Avago-technologies Cache Protection for RAID Controller Cards Manual do Utilizador Página 118

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 139
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 117
Avago Technologies
- 118 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 3: Monitoring and Managing Battery Backup Units and CacheVault Modules
Monitoring and Managing BBU Units with the MegaRAID Configuration Utilities
3.1.3.3 Display BBU Capacity
Use the command in the following table to display the BBU capacity for the selected controller or controllers.
For iBBU:
Relative State of Charge: xx
Charger System State: xx
Charger System Ctrl: xx
Charging Current: xx mA
Absolute State of Charge: xx%
Max Error: xx%
For BBU:
Relative State of Charge: xx
Charger Status: xx
Remaining Capacity: xx mAh
Full Charge Capacity: mAh
isSOHGood: Yes/No
Table 6 Display BBU Capacity Information
Convention MegaCLI -AdpBbuCmd -GetBbuCapacityInfo –aN|-a0,1,2|-aALL
Description Displays BBU capacity information. The information displays in the following format:
BBU Capacity Info for Controller: x
Relative State of Charge: xx%
Absolute State of Charge: xx%
Remaining Capacity: xx mAh
Full Charge Capacity: xx mAh
Run Time to Empty: xxx Hr yy Min
Average Time to Empty: xx Hr yy Min
Extimated Time to Full Recharge: XXXX(string)
Cycle Count: xx
Table 5 Display BBU Status Information (Continued)
Vista de página 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 138 139

Comentários a estes Manuais